300W
Server ,Workstation ,Storage System
207x85x84(mm)
8.15x3.35x3.31(inch)
VOLTAGE: 90~264VAC FULL RANGE
FREQUENCY: 47~63HZ
INPUT CURRENT:4.5A (RMS) FOR 115 VAC
2.0A (RMS) FOR 230 VAC
INRUSH CURRENT:15A MAX. FOR 115 VAC PER MODULE
30A MAX. FOR 230 VAC PER MODULE
Output Voltage | Output Current Min. | Output Current Max. | Regulation Load | Regulation Line | Output Ripple & Noise Max.[P-P] |
+5V | 0.5 | 20 | ±5% | ±1% | 50mV |
+12V | 2.0 | 24 | ±5% | ±1% | 120mV |
-12V | 0.1 | 0.5 | ±10% | ±1% | 120mV |
+3.3V | 0.5 | 20 | ±5% | ±1% | 50mV |
+5VSB | 0.1 | 2.5 | ±5% | ±1% | 50mV |
* TEMPERATURE RANGE:OPERATING 0℃~40℃, STORAGE -20℃~80℃
* HOLD UP TIME:WHEN POWER SHUTDOWN DC OUTPUT 5V MUST BE MAINTAIN 16MSEC IN REGULATION LIMIT AT NORMAL INPUT VOLTAGE
* EFFICIENCY:84% TYPICAL,AT FULL LOAD 115VAC
* LEAKAGE CURRENT: 3.5 MA. MAX. AT NOMINAL VOLTAGE 250VAC
* POWER GOOD SIGNAL:ON DELAY 100mS TO 550mS,OFF DELAY 1Ms
* OVER POWER PROTECTION:110~160% MAX
* OVER VOLTAGE PROTECTION: +5V→5.6~6.7V, +3.3V→3.6~4.3V, +12V→13~16V
* SHORT CIRCUIT PROTECTION: +5V, +3.3V, +12V, -12V, +5VSB
* SAFETY: MEET UL60950, TUV EN-60950, CB IEC 60950
* WARNING METHOD: AUDIO ALARM(BUZZER SOUND, RESETABLE), FALUT LED, TTL
*THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.