120W
Server
215x106x41.5(mm)
8.46x4.17x1.63(inch)
VOLTAGE: 90~264VAC FULL RANGE
FREQUENCY: 47~63HZ
INPUT CURRENT:2A (RMS) FOR 115 VAC
1A (RMS) FOR 230 VAC
INRUSH CURRENT:35A MAX. FOR 115 VAC PER MODULE
70A MAX. FOR 230 VAC PER MODULE
Output Voltage | Output Current Min. | Output Current Max. | Regulation Load | Regulation Line | Output Ripple & Noise Max.[P-P] |
+5V | 0 | 10 | ±5% | ±1% | 50mV |
+12V | 2 | 10 | ±5% | ±1% | 120mV |
+3.3V | 0 | 10 | ± 5% | ±1% | 50mV |
-12V | 0 | 0.3 | ±10% | ± 1% | 120mV |
+5VSB | 0.1 | 3 | ±5% | ±1% | 50mV |
* TEMPERATURE RANGE:OPERATING 0℃~50℃, STORAGE -20℃~80℃
* HOLD UP TIME:WHEN POWER SHUTDOWN DC OUTPUT 12V MUST BE MAINTAIN 17MSEC IN REGULATION LIMIT AT NORMAL INPUT VOLTAGE
* THE MAXIMUM POWER SUPPLY SYSTEM EFFICIENCY SHALL BE 86%, MEASURED AT NOMINAL INPUT VOLTAGE 230 V AND FULL LOADING(+12V:10A).
* LEAKAGE CURRENT: 3.5 MA. MAX. AT NOMINAL VOLTAGE 250VAC
* REMOTE ON/OFF CONTROL
* POWER GOOD SIGNAL:ON DELAY 100mS TO 550mS,OFF DELAY 1Ms
* OVER POWER PROTECTION:110~150% MAX
* OVER VOLTAGE PROTECTION: +5V→5.7~6.5V, +3.3V→3.7~4.1V, +12V→12.8~15V
* SHORT CIRCUIT PROTECTION: +5V, +3.3V, +12V, -12V, +5VSB
* SAFETY: MEET UL&CUL, TUV, CCC
* WARNING METHOD: AUDIO ALARM(BUZZER SOUND, RESETABLE), FALUT LED, TTL
* THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.